Shorted Capacitors: The Most Common Cause of No Power
Tools You'll Need
MultimeterDC power supplyHot air stationTweezers
For technicians: tiny capacitors filter the power lines. When one fails, it often shorts the whole line and the phone won't turn on.
1. Measure the main power lines (battery positive line, VBUS, VCC_MAIN) to ground.
2. If one is shorted, look up which capacitors are on it in the board view.
3. Inject low voltage and find the warm one (see our rosin tip).
4. Remove that capacitor with hot air or tweezers and measure again.
5. If the short is gone, most small filter capacitors can be left off temporarily for testing, then replaced with the same value.
Capacitors near the battery connector and charging port are the most likely to fail, especially after water or fake chargers.